10ZJ106蒸压加气溷凝土砌块外墙自保温.pdf
- 文档部分内容预览:
外墙热桥占整墙面比例(Q1)硬泡聚氨酯0.100.200.300.400.500.600.700.800.901.00Q2KDKDK.DK.DKnDK.DKDKDKDKeD0.000.583.740.653.320.723.120.793.000.862.920.932.861.002.811.072.771.142.721.212.650.100.603.730.693.300.783.090.872.970.962.881.042.821.132.771.222.731.312.701.402.67200.200.623.720.733.280.833.080.942.951.052.871.162.811.272.761.382.721.482.691.592.670.300.643.710.763.270.893.061.022.941.152.861.272.801.402.751.532.721.662.691.782.670. 000.553.850.593.460.643.260.683.150.723.070.763.000.802.950.852.890.892.830.932.740.100.573.840.643.420.703.220.773.090.833.000. 892.930.962.881.022.841. 092.801.152.760.200.603.820.683.400.773.190.853.070.942.981.022.911.112.861.202.831.282.791.372.770.300.623.810.733.390.833.180.943.051.052.971.162.901.262.861.372.821.482.791.592.770. 000.543.910.573.520.613.330.643.220.673.140.703.070.733.010.772.950.802.880.832.790.100.563.890.623.480.673.280.733.150.783.060.842.990.892.940.952.891.002.851.062.81350.200.593.880.673.460.743.250.823.120.903.030.982.971.052.921.132.881.212.841.292.810.300.613.860.713.440.813.230.913.111.013.021.112.961.212.911.322.871.422.841.522.820. 000.533.970.563.590.583.400.613.290.633.210.653.140.683.080.703.020.732.940.752.830.100.563.950.613.550.653.340.703.210.753.120.803.050.842.990.892.940.942.900.992.860.200.583.930.653.520.723.310.803.180.873.090.943.021.012.971.082.931.152.891.222.860.300. 613.910.703.500.803.290.893.160.993.071. 083.011.182.961.272.921.372.891.462.870.000.524.080.533.720.553.540.563.430.573.350.583.280.593.210.613.140.623.050.632.930.100.554.050.583.670.623.470.663.340.693.240.733.170.773.100.813.050.843.000.882.960.200.574. 030.633.630.703.420.763.290.823.200.883.130.943.081.003.031.072.991.132.960.300.604.010.683.610.773.400.863.270.943.181.033.111.123.061.203.021.292.991.382.96说明:1、表中K为外墙平均传热系数[W/(m.K),D为外墙热情性指标【无量纲],8为保温层厚度【],Q!为热桥部分与全墙外立面面积比例,Q2为无#面流五长养全博精战改:()热然录盒食保温热桥与全部热桥外立面面积的比例2、直接选用本表时,设计应符合本表给出的相关条件图集号10ZJ106B05/300一硬泡聚氨酯(三页47
外墙热桥占整墙面比例(Q)硬泡聚氨酯0.100.200.300.400.500.600.700.800.901.00Q2KDKDKDKDKDKeDKDKDK.DK.D0.000.723.600.773.270.833.100.882.990.942.920.992.861.052.811.102.771.162.721.212.650.100.733.590.813.250.883.070.962.961.032.881.102.821.182.771.252.731.332.691.402.67200.200.753.580.853.230.943.051.032.941.132.861.222.801.312.761.412.721.502.691.592.670.300.773.570.883.221.003.041.112.931.222.851.332.791.452.751.562.721.672.691.782.670. 000.693.700.713.400.743.240.773.130.803.060.823.000.852.950.882.900.902.830.932.740.100.713.680.763.360.813.190.863.080.903.000.952.931:002.881. 052.841.102.801.152.760.200.733.67803.340.873.170.943.052.971. 082.911.162.861.232.821.302.791.372.770.300.75660.853.330.943.151.033.042.961.222.901.312.851.402.821.492.791.592.770.000.68750.693.460.713.300.733.210.753.130.763.070.783.020.802.960.812.890.832.790.100.703.73743.420.783.250.823.140.863.060.902.990.942.940.982.891.022.851.062.810.200.723.720.793.400.853.220.913.110.973.031.042.961.102.911.162.871.232.841.292.810.300.753.700.833.380.923.201.003.091.093.011.172.951.262.901.352.871.432.841.522.820. 000.673.800.683.520.693.370.703.270.713.200.713.140.723.080.733.020. 742.950.752.830.100.693.780.733.480.763.310. 793.200.823.120.863.050.892.990.922.940.952.900.992.860.200.723.760.773.450.833.280.893.160.943.081.003.021.052.971.112.931.172.891.222.860.300.743.750.823.430.903.250.983.141.063.061.143.001.222.961.302.921.382.891.462.870.000.663.900.653.650.653.510.653.410.653.340. 643.280.643.220.643.150.633.060.632.930.100.683.870.703.590.733.430.753.320.773.230.793.160.813.100.843.050.863.000.882.96500.200.713.850.753.560.803.390.853.270.893.190.943.130.993.071.033.031.082.991.132.960.300.733.830.803.530.883.360.953.251.023.171.093.111.163.061.233.021.312.991.382.96说明:1、表中K为外墙平均传热系数[W/(m2K),D为外墙热情性指标[无量纲】6为保温层厚度[m],Q:为热桥部分与全墙外立面面积比例,Q2为无保温热桥与全部热桥外立面面积的比例2、直接选用本表时,设计应符合本表给出的相关条件图集号10ZJ106B06/250硬泡聚氨酯(五)49
硬泡聚氨酯外墙热桥占整墙面比例(Q:)0.100.200.300. 400.500.600.700.800.901.008Q2K.KDKDKDKDKDKDKKDKD0.000.933.300.963.110.993.011.022.941.062.881.092.841.122.801.152.761.182.721.212.650.100.953.291.003.101.052.981.102.901.152.841.202.801.252.761.302.721.352.691.402.67200.200.973.281.043.081.112.961.182.881.252.831.322.781.382.741.452.711.522.691.592.670.300.993.271.083.071.162.951.252.871.342.821.432.771.522.741.612.711.692.691.782.670.000.903.380.913.220.913.130.913.070.923.020.922.980.922.940.922.890.932.840.932.740.100.923.360.953.200.973.091.003.021.022.961.052.911.072.871.102.831.122.801.152.76300.200.953.350.993.181.043.071.092.991.132.931.182.891.232.851.272.821.322.791.372.770.300.973.34.043.161.113.051.172.971.242.921.312.871. 382.841.452.811.522.791.592.77000.893.42.893.280.883.190.873.130.873.080.863.040.853.000.842.960.842.890.832.790.100.923.40933. 250.953.150.963.070.983. 011.002.971.012.921.032.88.042.851.062.81350.200.943.390.983.221.023.121.063.041,092.981.132.941.172.901.212.871.252.841.292.810.300.963.37023.201.093.101.153.021.212.971.272.921.332.891.392.861.462.841.522.820.000.893.450.873.330.863.250.843.200.833.150.813.110.803.070.783.020.772.950.752.830.100.913.44.923.290.933.200.933.130.943.070.953.020.962.980.972.94.982.900.992.860.200.933.420.963.271.003.171.033.091.063.041.092.991.132.951.162.921.192.891.222.860.300.963.41013.251. 073.141.123.071.183.021.242.971.292.941.352.912.891.462.870.000.873.530.853.430.823.370.793.320.773.280.743.240.713.200.683.150.663.070.632.930.100.903.500.903.390.893.300.893.240.893.180.893.130.893.090.883. 040.883.000.882.96500.200.923.480.953.350.973.260.993.191.013.141.043.091.063.051.083.021.112.991.132.960.300.953.471.003.331.043.231.093.171.143.111.193.071.233.041.283.011.332.981.382.96说明:1、表中K为外墙平均传热系数【W/(mK),D为外墙热情性指标【无量纲】6为保温层厚度[mm],Q!为热桥部分与全墙外立面面积比例,Q2为无保温热桥与全部热桥外立面面积的比例2、直接选用本表时,设计应符合本表给出的相关条件,图集号10ZJ106B07/200硬泡聚氨酯(七)51
硬泡聚氨酯外墙热桥占整墙面比例(Q:)0.100.200.300.400.500.600.700.800.901.00Q2KDK.DKDKDKDKDKDKDKDKaD0.000.793.640.833.310.883.130.933.020.982.941.022.881,072.831.122.781.162.731.212.650.100.813.630.873.290.943.111.002.991.072.901.142.841.202.781.272.741.332.701.402.67200.200.833.620.913.281.003.091.082.971.172.881.252.821.342.771.422.731.512.701.592.670.300.843.620.953.271.053.081.162.961.262.871.372.811.472.761.572.731.682.691.782.670.000.763.740.783.430.803.270.823.160.843.080.853.020.872.960.892.910.912.840.932.740.100.783.720.823.410.863.230.903.110.943.020.992.951.032.901.072.851.112.801.152.76300.200.803.710.873.390.933.200.993.081.052.991.122.931.182.881.242.831.312.801.372.770.300.823.700.913.370.993.183.061.162.981.252.921.332.871.422.831.502.791.592.770.000.753.790.763.490.773.330.783.230.793.150.793.090.803.030.812.970.822.900.832.790.100.773.770.803.460.843.290.873.170.903.080.933.010.962.951.002.901.032.851.062.81350.200.793.760.853.440.903.260.963.141.013.051.072.981.122.931.182.881.232.851.292.810.300.823.740.903.420.973.241.053.121.133.031.212.971.282.921.362.881.442.841.522.820.000.743.830.743.550.743.400.743.300.753.220.753.160.753.100.753.040.752.960.752.830.100.763.810.793.520.813.350.843.230.863.140.893.070.913.010.942.950.962.910.992.86400.200.793.800.843.490.893.310.933.190.983.111.033.041. 082.981.132.941.182.901.222.860.300.813.780.883.470.963. 291.033.171.103.091.173.021.242.971.322.931.392.891.462.870.000.733.920.723.670.713.530.703.430.693.360.673.300.663.230.653.170.643.080.632.930.100.753.903.630.783.460.803.350.813.260.823.180.843.120.853.060.873.010.882.96500.200.783.880.823.590.863.420.903.300.933.210.973.141.013.091.053.041.093.001.132.960.300.803.860.873.570.933.390.993.281.063.191.123.121.193.071.253.031.312.991.382.96说明:1、表中K.为外墙平均传热系数[W/(mK),D为外墙热情性指标【无量纲】8为保温层厚度【mm],Q:为热桥部分与全请外立面面积比例,Q2为无保温热桥与全部热桥外立面面积的比例。2、直接选用本表时,设计应符合本表给出的相关条件图集号10ZJ106B07/250硬泡聚氨酯(八)页52
硬泡聚氨酯外墙热桥占整墙面比例(Q1)0.100.200.300.400.500.600.700.800.901.00Q2K.DKDKaDKDKDKDKDKDDKoD0.000.703.920.753.450.813.220.873.080.932.980.982.911, 042.841.102.791.152.731.212.650.100.723.910.793.440.873.190.943.041.022.941.102.861.172.801.252.751.322.701.402.670.200.743.900.833.420.933.181.023,031.122.921.212.851.312.791.402.741.502.701.592.670.300.753.890.873.410.983.171.103.011.212.911.332.841.442.781.552.731.672.701.782.670.000.674.030.703.590.733.360.763.220.793.120.813.050.842.980.87920.902.850.932.740.100.690.743.560.793.320.843.170.893.060.952.981.002.911.05861.102.811.152.760.200.710.793.540.863.300.933.141.003.041.082.961.152.891.222.841.302.801.372.770.300.733.990.833.520.923.281. 023.131.113.021.212.941.302.881.402.841. 492.801.592.770.000.664.080.683.650.703.430.723.290.743.190.753.120.773.050.792.980.812.910.832.790.100.68060.723.620.773.380.813.230.853.120.893.040.932.970.982.91022.861.062.810.200.704.050.773.600.833.350.903.200.963.091.033.011. 092.951.162.901.222.851.292.810.300.734. 040.823.580.903.330. 993.181.083.081.173.001.252.941.342.891.432.851.522.820.000.654.130.663.720.673.500.683.360.703.270.713.190.723.120.733.050.742.960.752.830.100.674.110.713.680. 743.450.783.290.813.180.853.100.883.030.922.970.952.910.992.860.200.704.100.763.650.823.410.873.260.933.150. 993.071. 053.001.112.951.172.901.222.860.300.724.080.803.630.893. 390.973.241.053.131.133.051.212.991.302.941. 382.901.462.870.000.644.240.643.840.643.640.643.500.643.410.633.330.633.260.633.180.633.080.632.930.100.664.210.693.800.713.570.743.420.763.310.783.220.813.140.830.863.010.882.960.200.694.190.743.770.793.530.843.370.883.260.933.180.983.111.033.051.083.001.132.960.300.714.180.793.740.863.500.933.351.013.241.083.161.163.091.233.041.303.001.382.96说明:1、表中K为外墙平均传热系数[W/(m7.K),D为外墙热情性指标【无量纲】8为保温层厚度【m],Q为热桥部分与全墙外立面面积比例,Q2为无保温热桥与全部热桥外立面面积的比例,2、直接选用本表时,设计应符合本表给出的相关条件图集号10ZJ106B07/300硬泡聚氨酯(九)53
硬泡聚氨酯外墙热桥占整墙面比例(Q)0.100.200.300.400.500.600.700.800.901.00Q2KDKDKDKDKnDKDKDKDKDKD0.000.763.980.813.510.863.260.913.110.963.001.012.921.062.861.112.801.162.741.212.650.100.783.970.853.490.923.240.993.081.062.961.122.881.192.811.262.761.3312.711.402.67200.200.803.960.893.480.973.221.063.061.152.951.242.8611332.801.4221751.502.701.592.670.300.823.960.923.471.033.211.143.051.252.941.352.861.462.791.572.741.682.701.782.670.000.734.080.753.630.783.400.803.250.823.140.843.060.862.990.892.930.912.860.932.740.100.754.070.803.610.843.360.893.200.933.090.973.001.022.931.062.871.112.811.152.76300.200.784.063.590.913.340.973.181.043.061.102.981.172.911.242.851.302.811.372.770.300.804.053.58973.32063.161.153.051.242.961.322.901.412.851.502.801.592.770.000.724.130.733.700.753.470.763.320.773.220.783.130.793.060.812.990.822.910.832.790.100.744.120.783.670.813.420.853.260.883.150.923.060.952.990.992.921.022.861.062.81350.200.774.100.833.650.883.400.943.231.003.121.063.031.112.961.172.901.232.861.292.810.300.794.090.873.630.953.381.033.221.113.101.193.021.272.951.362.901.442.851.522.820.000.714.180.723.760.723.530.733.390.733.290.733.200.743.130.743.060.752.970.752.830.100.744.170.773.730.793.490.823.330.853.210.883.120.903.040.932.980.962.920.992.86400.200.764.150.813.700.863.460.923.290.973.181.023.091. 073.021.122.961.172.911.222.860.300.794.140.863.680.943.431.013.271.093.161.163.071.243.001.312.951.392.901.462.870.000.704.280.693.890.693.670.683.530.673.430.663.340.653:270.653.190.643.090.632.930.100.734.260.743.840.763.610.783.450.793.330.813.243.16503.09020.882.960.200.754.240.793.810.843.370.883.410.923.290.963.201.003.121.043.061,093.011.132.960.300.784.230.843.790.913.540.983.381.043.261.113.181.183.111.243.051.313.001.382.96说明:1、表中K为外墙平均传热系数【/(m·K,D为外墙热情性指标【无量纲】6为保温层厚度[mm],Q:为热桥部分与全墙外立面面积比例,Q2为无保温热桥与全部热桥外立面面积的比例2、直接选用本表时,设计应符合本表给出的相关条件图集号10ZJ106B08/300硬泡聚氨酯(十二)56
外墙热桥占整墙面比例(Q:)B05加气混凝土砌块0.100.200.300.400.500.600.700.800.901.00K.DDK.DKDK.DK.DKKDKDKDQ2200厚B05加气混凝土外墙0.000.813.480.903.400.993.361.083.331.183.311.273.301.363.281.453.281.543.271.633.260.100.833.450.933.351.043.291.143.241.253.201.363.181.463.151.573.131.673.121.783.10500.200.843.430.963.311.083.241.203.191.323.151.443.121.573.101.693.081.813.061.933.050.300.863.410.993.281.133.211.263.151.403.121.533.091.673.061.813.051.943.032.083.020.100.783.750.843.780.893.790.953.791.013.781.073.781.133.771.193.761.243.751.303.741000.200.803.710.883.710.963.701.033.691.113.671.193.661.273.651.353.641.433.631.503.630.300.823.660.923.651.023.631.113.621.213.611.313.601.413.591.513.581.613.571.713.57Q2250厚B05加气混凝土外墙0.000.703.820.813.600.913.491.013.421.123.371.223.341.323.311.423.291.533.281.633.260.100.723.800.843.550.953.411.073.331.193.261.313.221.433.181.543.151.663.121.783.10500.200.733.770.873.511.003.371.133.271.263.211.403.161.533.121.663.091.803.071.933.050.300.753.750.903.481.043.331.193.241.343.181.493.131.633.091.783.061.933.042.083.020.100.674.220.744.090.814. 010.883.940.953.891. 023.851.093.821.163.791.233.761.303.741000.200.694.170.784.020.873.910.963.841.053.781.143.741.233.701.323.671.413.651.503.630.300.714.130.823.960.933.851.043.771.153.721.263.671.373.641.483.611.603.591.713.57toQ2300厚B05加气混凝土外墙0.000.624.090.733.740.853.570.963.471.073.411.183.361.293.331.413.301.523.281.633.260.100.644.060.763.690.893.501.023.381.143.301.273.241.403.201.533.161.653.131.783.10500.200.654.030.793.650.943.451.083.331.223.251.363.191.503.141.643.101.793.071.933.050.300.674.010.823.620.983.421.:143.301.293.211.453.151.613.111.763. 071.923.042.083.020.100.594.560.674.290.754.140.834.030.913.950.993.891.063.841.143.801,223.771.303.741000.200.614.510.714.210.814,040.913.931.013.841.113.781.213.731.313.691.403.651.503.630.300.634.470.754.160.873.980.993.861.113.781.233.721.353.671.473.631.593.601.713.57B05/200~300图集号说明同56页10ZJ106加气混凝土块一57
外墙热桥占整墙面比例(Q)B05加气0.100.200.300. 400.500.600.700.800.901.00混凝土砌块K.DKDKaDKDKDKDKDKDKDKDQ2200厚B08加气混凝土外墙0.001.053.521.123.441.183.391.253.361.313.331.373.311.443.291.503.281.573.271.633.26R0.101.073.501.153.401.233.331.313.281.383.241.463.201.543.171.623.151.703.121.783.10500.201.083.491.183.371.273.291.373.231.463.191.553.151.653.121.743.091.833.071.933.050.301.103.471.213.351.323.261.423.201.533.151.643.121.753.091.863.061.973.042.083.020.101.023.741.053.781.083.791.113.791.153.791.183.781.213.781.243.761.273.751.303.741000.201.043.711.093.711.143.711.203.701.253.691.303.681.353.661.403.651.453.641.503.630.301.063.671.133.661.203.651.283.631.353.621.423.611.493.601.563.591.633.581.713.57Q2250厚B08加气混凝土外墙0.000.913.950.993.701.073.571.153.481.233.421.313.371.393.331.473.311.553.281.633.260.100.923.921.023.671.113.511.213.401.303.321.403.261.493.211593.171.683.131.783.10500.200.943.911.053.631.163.471.273.361.383.271.493.211.603.161.713.111.823.081.933.050.300.953.891.083.611.203.441.333.321.453.241.583.171.703.121.833.081.953.052.083.020.100.884.280.924.160.974.071.024.001.073.941.113.891.163.851.213.811.253.771.303.741000.200.904.240.964.101.033.991.103.911.173.841.233.781.303.741.373.691.443.661.503.630.300.924.211.014.051.093.931.183.841.273.771.363.721.443.671.533.631,623.601.713.57Q2300厚B08加气混凝土外墙0.000.804.280.893.900.993.691.083.561.173.471.263.411.353.361.453.321.543.291.633.260.100.824.260.923.861.033.631.143.481.243.381.353.301.463.241.573.191.673.141.783.10500.200.834.240.953.821.083.591.203.441.323.331.443.251.563.181.683.131.813.081.933.050.300.854.230.983.801.123.561.263.401.393.291.533.211.673.151.803.101.943.052.083.020.100.774.700.834.420.894.250.954.121.014. 031.073.951.123.891.183.831.243.781.303.741000.200.794.660.874.360.954.171.034.031.113.931.193.841.273.771.353.721.423.671.503.630.300.814.630.914.311.014.111.113.961.213.861.313.781.413.711.513.651.613.611.713.57意示1袁点节B08/200~300图集号说明同56页10ZJ106加气混凝土砌块(四)页60
、协编单位在本图集编制过程中,提供了相关技术资料,给予了工作支持。 、本附录主要为广大用户选用相关产品提供方便漆包线标准,其中产品性能介绍仅供参考。由于同一产品 的厂家众多,产品本身也不断革新变化,选用人应结合单项工程实际选用符合国家和行业现 行有关标准的产品。斯面联防水裤然育味录谦高然奥文龙·卧单衣 为使广大用户能及时了解最新的产品信息,欢迎相关科研院所、生产单位作为协编单位参与 中南地区建筑标准设计图集编制
协编单位:河南华伟佳科技有限公司
协编单位:武汉三木建材有限责任公司
协编单位:南阳欧典新型墙体材料开发有限公司
....- 相关专题: 外墙自保温